Nimac

Nimac Power Systems (M) Sdn Bhd

Product Category




UPS System

ESCORT Series On Line Uninterruptible Power Systems

The Escort-series is true on line double conversion topology, high efficiency operation, true isolation, input power factor correction and superior output voltage regulation. The Escort series has a wide input range mains voltage from 165v ~ 272v (220v), 90v ~ 132v (110v) against heavy discharges ensuring that batteries are reversed for emergency conditions. It provides regulated output for the fileservers, workstations and for all of emergency products to be powered.

Three Phase LUP Series Technology Specifications.

Model LUF-1000 LUF-1500 LUF-2000 LUF-3000
Capacity 1 KVA 1.5 KVA 2 KVA 3 KVA
Input Voltage 165V~272V(230V), 90V~140V(115V)
Frequency 50 or 60 Hz ±5%
Phase >0.97
Output Voltage 115V or 208V, 230V
Phase 1ø2W+G
Voltage Regulation ±1% at linear load
Frequency 50 or 60 Hz ±5%
Power Factor 0.7
Waveform Distortion Pure sinewave less than 3% at full load
Crest Factor 3 : 1
Overload Capacity 100% continuous, 150% for 25 seconds
Efficiency AC to AC >80% at battery fully charge
Battery Type 12V 7AH 3 pcs 12V 7AH 4 pcs 12V 7AH 8 pcs 12V 34AH 8 pcs
Back up Time Computer load 15~30 min.
Recharge Time 4~8 hours 90% after fully discharge
Transfer Time Bypass to UPS No break
UPS to Bypass < 2 ms
Indicator Multi function LED Display Line, Inverter, Bypass, Fault, Battery/ Load level
Audible Alarm 1) AC Failure Sound every 4 seconds after line fails
2) Battery Low Sound every second when approaches battery low level
3) UPS Fault Continuous alarm
Protection Over/under voltage at I/P Yes
Short Circuit & overload The UPS shuts down and will not transfer to the bypass mode when a short circuit occurs on the output of the unit. After the short circuit being  removed the UPS will operate normally again. At short condition, the Fault LED lights as a warning to end users.
  Lighting: Yes. Surge: Yes.
Environment Temperature 0°C to 40°C
Humidity 0°C to 90°C at non condensing
Noise Level <45dB at 1 meter
Connection Interface Port DB-9 connector (option)
Dimension WxDxH (mm) 145 x 240 x 480 145 x 310 x 480 210 x 430 x 550 210 x 430 x 550
Weight Net Weight 18 kgs 28 kgs 43 kgs 50 kgs

Single Phase LUV Series Technology Specifications.

Model LUV
-50
LUV
-60
LUV
-80
LUV
-100
LUV
-150
LUV
-200
LUV
-300
Capacity 5KVA 6KVA 8KVA 10KVA 15KVA 20KVA 30KVA
Input
(Rectifier)
Voltage 110V or 220V ± 15%
Frequency 50 or 60 Hz ± 5%
Phase 1ø2W+G or 3ø3W+G, 3ø4W+G
Output
(inverter)
Voltage 115V or 208V, 230V
Phase 1ø2W+G or 1ø3W+G (option)
Voltage Regulation ± 1% at linear load
Frequency 50Hz or 60Hz ± 0.5%
Power Factor 0.8
Waveform Distortion Less than 3% at linear load
Crest Factor 3 : 1
Overload Capacity 100% continuous, 150% for 25 seconds
Efficiency AC to AC >85% at battery fully charge
Battery Voltage 192V (12V x 16pcs) 240V
Back up Time Computer load 15~30 min.
Recharge Time 4~8 hours 90% after fully discharge
Transfer
Time
Mains <> Inverter No break
Indicator LCD Display Input/Output voltage, Frequency, Output current percentage, Battery voltage, Operating temperature.
LED Display Mimic display
Audible
Alarm
Battery Discharge Sound every 4 seconds. Sound every 1 second for battery low.
UPS Fault Continuous sound
Protection Output Short Yes
Lightning Yes
Environment Temperature 0°C to 40°C
Humidity 0 to 90%, non condensing
Noise Level < 50dB at 1 meter < 60dB at 1 meter
Communication Interface Port RS-232 or AS-400
Dimension 
(WxHxD) (mm)
UPS 260 x 800 x 660 260 x 900 x 660 310 x 900 x 660 360 x 740 x 870
Battery Bank 360 x 740 x 870
Net Weight UPS 130kgs 160kgs 190kgs 320kgs 190kgs 230kgs 280kgs
Battery Bank 200kgs 200kgs 290kgs